Problem:

Debris from plastic molding operation falling on magnetic media caused head crash during disk read and write operations. Static electricity made it difficult to remove the debris using conventional methods, not to mention the time it took to manually clean these cartridges.

Solution:

Make a debris removal chamber composed of :

· Enclosed Chamber

· Multiple Ionized Air nozzles

· Air Blower; Low Pressure—High Velocity

· Hepa Filters

· Vacuum

· Conveyors—Aluminum Roller

· Anti Static Air Blowers

Results:

· Reduced labor time due to elimination of hand cleaning.

· Increased efficiency due to a controlled procedure, therefore more consistent results.

· Increased yield resulting from reduced damage caused by falling debris on disk surface.